Insulation Resistance Measurement
|
Test voltage (DC)
|
250 V
|
< 250 kΩ,
250 kΩ to 5 GΩ
5 GΩ to 50 GΩ
> 50 GΩ
|
Unspecified
5%
20%
Unspecified
|
500 V
|
< 500 kΩ
500 kΩ to 10 GΩ
10 GΩ to 100 GΩ
> 100 GΩ
|
Unspecified
5%
20%
Unspecified
|
1000 V
|
< 1 MΩ
1 MΩ to 20 GΩ
20 GΩ to 200 GΩ
> 200 GΩ
|
Unspecified
5%
20%
Unspecified
|
2500 V
|
< 2.5 MΩ
2.5 MΩ to 50 GΩ
50 GΩ to 500 GΩ
> 500 GΩ
|
Unspecified
5%
20%
Unspecified
|
5000 V
|
< 5 MΩ
5 MΩ to 100 GΩ
100 GΩ to 1 TΩ
> 1 TΩ
|
Unspecified
5%
20%
Unspecified
|
Bar graph range
|
0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)
|
Insulation test voltage accuracy
|
-0%, +10% at 1 mA load current
|
Induced AC mains current rejection
|
2 mA maximum
|
Charging rate for capacitive load
|
5 seconds per μF
|
Discharge rate for capacitive load
|
1.5 s/μF
|
Leakage current measurement
|
Range
|
1 nA to 2 mA
|
Accuracy
|
± (5% + 2 nA)
|
Capacitance measurement
|
Range
|
0.01 μF to 15.00 μF
|
Accuracy
|
± (15% rdg + 0.03 μF)
|
Timer
|
Range
|
0 to 99 minutes
|
Resolution setting
|
1 minute
|
Resolution indication
|
1 second
|
Live circuit warning
|
Warning range
|
30 V to 660 V AC/DC, 50/60 Hz
|
Voltage accuracy
|
± (15% + 2 V)
|
Software specifications
|
FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
|
General Specifications
|
Display
|
75 x 105 mm
|
Power
|
12 V lead-acid rechargeable battery, Yuasa NP2.8-12
|
Charger Input (AC)
|
85 V to 250 V AC 50/60 Hz 20 VA
|
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
|
Dimensions
|
269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
|
Weight
|
3.7 kg (8.2 lb)
|
Temperature (operating)
|
-20°C to 50°C (-4°F to 122°F)
|
Temperature (storage)
|
-20°C to 65°C (-4°F to 149°F)
|
Humidity
|
80% to 31°C decreasing linearly to 50% at 50°C
|
Altitude
|
2000 m
|
Enclosure sealing
|
IP40
|
Input overload protection
|
1000 V AC
|
Electromagnetic compatibility
|
EN 61326
|
Safety compliance
|
IEC 61010-1: Overvoltage category II, Pollution Degree 2.
IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
IEC 61557-1, IEC 61557-2
|